Note:
When the ground fault monitoring initiates a fault for overlapping synchronizing the threshold value p0287[1] for the
Motor Module and the associated infeed must be appropriately increased (e.g. p0287[1] = 100 %).
For p3800 = 1, the following applies:
The INTERNAL voltage actual values are used for synchronization. The effects that a (sine-wave) filter - that is
connected between the Motor Module and motor - has on the voltage actual values are taken into account
(theoretically) by appropriately selecting p0230.
VSM: Voltage Sensing Module
p3801[0...n]
Sync-line-drive drive object number / Sync DO_no
VECTOR_G
Can be changed: T
Data type: Unsigned16
P-Group: Functions
Not for motor type: -
Min
1
Description:
Sets the drive object number of the VSM used for the line-drive synchronization.
Dependency:
Refer to: p3800, p3802
Notice:
The current controller sampling time p0115[0] of the drive object with the VSM used for synchronization must be
identical to the current controller sampling time of the drive of the drive used to perform line synchronization.
Note:
VSM: Voltage Sensing Module
The setting p3801 = 1 is always possible (no VSM selected).
If the VSM is assigned subsequently to a Motor Module, its drive object number must be entered in p3801.
The line voltage is always measured using the first VSM (p0151[0]).
p3802[0...n]
BI: Sync-line-drive enable / Sync enable
VECTOR_G
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Functions
Not for motor type: -
Min
-
Description:
Sets the signal source to switch in/switch out for the line-drive synchronization.
BI: p3802 = 1 signal:
The line-drive synchronization is switched in.
Dependency:
Refer to: p3800, p3801
r3803.0
CO/BO: Sync-line-drive control word / Sync STW
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Functions
Not for motor type: -
Min
-
Description:
Displays the control word for the line-drive synchronization.
Bit field:
Bit
00
Note:
For bit 00:
For a 1 signal, p3800 > 0 is set.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Sync-line-drive selected
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
62
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 7020
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 7020
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
FP
-
617