56.6 Stop

Proceed as follows:
1 Open the main window (see section 56.5.1)
2 Go to File > Exit. The cross in the upper right hand
corner of the main windows does not stop the
Logging Server.
Message:
The Logging Server database has reached its critical
size. Please decrease the logging expiration periods.
Description:
The database has reached its critical size.
Recommended action:
Enable and decrease the logging expiration periods to
move events to the overflow files (see section 56.7.3)
or flush the database (see section 56.7.4.4).
Message:
The Logging Server overflow files have reached their
critical size. Please clear or delete the overflow files.
Description:
One or more overflow files have reached the critical
size.
Recommended action:
The overflow files are comma separated value (*.csv)
files. They can be opened in an editor (e.g. Windows
Wordpad, Microsoft® Excel). When an overflow file
reaches its critical size, use an editor to delete data
from the overflow file and decrease its size.
Bosch Security Systems | 2011-02

56.7 Configuration

56.7.1 Introduction
1 Open the main window (see section 56.5.1).
2 Click File > Options. A screen similar to the one in
figure 56.5 appears.
figure 56.5: Options window
3 Go to the Connections tab to define the connections to
the systems of which the events must be logged (see
section 56.7.2).
4 Go to the Logging Expiration tab to specify the
expiration periods of the logged events (see section
56.7.3).
5 Go to the Database tab to define the properties of the
logging database (see section 56.7.4).
6 Go to the Security tab to change the security settings
of the logging server (see section 56.7.5).