Connections - Bosch Praesideo 3.5 Installation And User Instructions Manual

Digital public address and emergency sound system
Table of Contents

Advertisement

Praesideo 3.5 | Installation and User Instructions | 6 | Installation Accessories

25.3 Connections

25.3.1 Introduction
This section gives an overview of typical system
connections using the network splitter:
Looping through the main branch (see section 25.3.2).
Creating tap-offs (see section 25.3.2).
Connecting an external power supply (see
section 25.3.3).
25.3.2 Connecting the main branch and
creating tap-offs
See figure 25.5 for information about connecting the
main network and the tap-offs to the network splitter.
tap-off 1
tap-off 2
figure 25.5: Connecting the network splitter
Bosch Security Systems | 2011-02
main branch
2
3
7
8
main branch
25.3.3 Connecting a power supply
This unit is powered by the network controller, via the
Praesideo system bus. But the network splitter is
delivered with a separate Kycon KPP4-P connector to
connect an external power supply to the network
splitter.
Note
The external power supply can only feed the
tap-offs and not the main network branch.
Whether it really does depends on the jumper
settings inside the network splitter.
The Kycon KPP-4P connector has four pins (see
figure 25.6):
figure 25.6: Connection diagram (external view)
table 25. 1 : Kycon KPP-4P connector details
Pin
Signal
1
Ground
2
Power from external power supply to the
PRS-NSP (max. 48 V / 5 A)
3
Output power from the system bus
(max. 48V / 2 A)
4
Not connected