Praesideo 3.5 | Installation and User Instructions | 7 | System Hardware Installation
31.6

Bending and coiling

31.6.1 Introduction
The POF cable may be bend or coiled. However, the
rules in this chapter must be observed.
31.6.2 Bending
The bend radius is 110 mm (see figure 31.6). The
maximum number of bends in a POF cable is 5.
R=110 mm
figure 31.6: Bend radius
A 180 degree bend equals two bends (see figure 31.7)
figure 31.7: U curve
Bosch Security Systems | 2011-02
1
2
R=110 mm
31.6.3 Coiling
The minimum coiling radius is 110 mm (see figure 31.8)
figure 31.8: Coiling radius
en | 298
R=110 mm