43.4.3 General (LBB4433/00)
figure 43.23: Configure call station, step 3
table 43. 1 1: General configuration settings (LBB4433/00)
Item
Class
Clear selection after call
Network power
supervision
Back-up power
supervision
Bosch Security Systems | 2011-02
Value
Description
Normal
Sets the priority range of the call station. This is either Normal
Emergency
for 32 to 223 or Emergency for 32 to 255. When Class is
Emergency the call station can make fail-safe calls.
Yes
Selects whether selections that are made on a keypad for a call
No
(zone selection, priority selection, tone selection and message
selection) will be cleared after the call has finished or will be
kept for a next call.
On
When Network power supervision is On and the network
Off
power is failing, a fault event is generated.
On
When Back-up power supervision is On and the back-up
Off
power is failing, a fault event is generated.