Bosch Praesideo 3.5 Installation And User Instructions Manual page 230

Digital public address and emergency sound system
Table of Contents

Advertisement

2011-02 | Installation and User Instructions | 5 | Call Stations
19.2.3 Keypad interface (X5, X6)
The external interface for connecting the keypad to
other keypads or to a (remote) call station consists of a
IDC connector with 16 positions (see the PCB for the
pin numbering). Keypads are connected in series to a
call station. This means that there is only a direct
connection between the call station and the first keypad.
The second keypad is connected to the first, the third to
the second etc. using standard flat cables.
table 19.5: X5 and X6 connector details
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Bosch Security Systems | 2011-02
Signal
Synchronization line.
GND
Interrupt line (INT)
GND
Data I2C (SDA)
GND
Clock I2C (SCL)
GND
Power
GND
Power
GND
Power
GND
Power
GND
19.2.4 ID selector (S9)
It is possible to connect:
Up to 16 call station keypads for pre-configured
actions (LBB4432/00 or LBB4434/00) to a (remote)
call station.
Up to 15 call station keypads for pre-configured
actions (LBB4432/00 or LBB4434/00) and one
numeric keypad (PRS-CSNKP) to a (remote) call
station.
For a correct communication between the call station
and its keypads, the correct ID must be assigned to each
keypad for pre-configured actions using the ID selector
(see figure 19.2, no. S9 and figure 19.7).
The ID of a keypad for pre-configured actions depends
on its position in the array of keypads. The first keypad
for pre-configured actions has ID 0, the next 1, and so
on up to F for the sixteenth keypad for pre-configured
actions.
E
C
A
figure 19.7: ID selector
en | 230