Toshiba e-STUDIO206L Service Manual page 607

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

Parts to be replaced
Separation roller
Pickup roller
Transfer roller
[E270] Bypass transport jam (Paper not reaching the registration sensor)
[E280] ADU transport jam (Paper not reaching the registration sensor)
Classification
Paper transport jam
Proce
Check item
dure
1
Open the Automatic
duplexing unit. Is there
paper in front of the
registration sensor?
2
Is the registration sensor
working?
(Perform the input check
in the test mode: 03-
[FAX]ON/[9]/[A]
3
Is the bypass feed clutch/
ADU clutch working?
(Perform the output check
in the test mode: 03-204/
222)
4
Registration roller
Parts to be replaced
Registration sensor.
LGC board
Bypass feed clutch
ADU clutch
Registration roller
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Error content
Jam not reaching the registration sensor
Result
Yes
Remove the paper.
No
Yes
No
Check if the connector of the registration
sensor is disconnected.
Check if the connector CN316 on the LGC
board is disconnected.
Check if the connector pins are
disconnected and the harnesses are open
circuited.
Check if the conductor pattern on the LGC
board is short circuited or open circuited.
Replace the registration sensor.
Replace the LGC board.
Yes
No
Check if the connector of the bypass feed
clutch/ADU clutch is disconnected.
Check if the connector CN311 on the LGC
board is disconnected.
Check if the connector pins are
disconnected and the harnesses are open
circuited.
Check if the conductor pattern on the LGC
board is short circuited or open circuited.
Replace the bypass feed clutch/ADU clutch.
Replace the LGC board.
Check the registration roller. Replace it if it
is worn out.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
8 - 47
Remark
Measure
Remark
ERROR CODE AND TROUBLESHOOTING
Next
Step
2
3
8
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents