Adjustment Procedure Summarization For A To E - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

<Adjustment procedure summarization for A to E>
e-STUDIO206L/256/306/356/456/506:
When the value is 1.
[0] [5] [Power ON]  [1] ([3](05-4062, 4019) for duplexing)  [FAX]
A:
05-4001 (Lower drawer, A3/LD)
B:
05-4006 (Lower drawer, A3/LD)
C:
05-4009 (Lower drawer, A3/LD)
D:
05-4058 (Lower drawer, A3/LD), 4059 (Lower drawer, A4/LT), 4060 (PFP, A4/LT),
4063 (LCF, A4/LT), 4061 (Bypass feed, A4/LT), 4062 (Duplexing, A3/LD)
E:
05-4019-0 (Lower drawer, A3/
LD), 4019-1 (Lower drawer, A4/
LT))
e-STUDIO207L/257/307/357/457/507:
When the value is 1.
[0] [5] [Power ON]  [1] ([3](05-4062, 4019) for duplexing)  [FAX]
A:
05-4001 (Lower drawer, A3/LD)
B:
05-4006 (Lower drawer, A3/LD)
C:
05-4009 (Lower drawer, A3/LD)
D:
05-4058 (Lower drawer, A3/LD), 4059 (Lower drawer, A4/LT), 4060 (PFP, A4/LT),
4063 (LCF, A4/LT), 4061 (Bypass feed, A4/LT), 4062 (Duplexing, A3/LD)
E:
05-4019-0 (Lower drawer, A3/
LD), 4019-1 (Lower drawer, A4/
LT))
Remarks:
When the adjustment (05-4009) is performed, the same adjustment for FAX (05-4010) is
automatically and consecutively performed.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
 200±0.5 mm (0.125 mm/step)
 52±0.5 mm (0.05 mm/step)
 Key in the same value for 05-4005.
 200±0.5 mm (0.125 mm/step)
 52±0.5 mm(0.4 mm/step)
 52±0.5 mm (0.05 mm/step)
 200±0.5 mm (0.15 mm/step)
 52±0.5 mm (0.0423 mm/step)
 Key in the same value for 05-4005.
 200±0.5 mm (0.25 mm/step)
 52±0.5 mm (0.54 mm/step [e-STUDIO207L/257/307]
 52±0.5 mm (0.84 mm/step [e-STUDIO357/457/507]
 52±0.5 mm (0.5 mm/step)
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
6 - 13