7.4
PM Support Mode (6S)
7.4.1
General description
The timing for the parts replacement usually depends on the number of output pages ever printed after
they were replaced before. However, the life span of them changes depending on the general use of
users and the environment in which the equipment is placed. Therefore, it is necessary to consider not
only the number of output pages but also the drive counts when deciding the timing for the parts
replacement in order to utilize the parts and materials effectively.
This equipment has the PM support mode, which makes it possible to see the general use of each part
(the number of output pages, drive counts) and replacement record and to do a counter clearing
operation more efficiently when replacing.
The replacement record can be printed out in the list printing mode (9S-103).
7.4.2

Operational flow and operational screen

[ 1 ] Operational flow

PM support mode activated

[6] + [START] + [POWER] ON
Authentication screen
Serf-diagnosis mode screen
[RETURN] pressed
Main screen
Main unit list displayed
[CANCEL] pressed
Clear screen
Counter clear
confirmation displayed
Clear finished
Counter clear performed
* When the authentication screen appears, press [OK]. (Enter the password, if one has been set.)
* The screen goes back to the main screen when the counter clear is executed or the [CANCEL]
button is pressed after moving from the main screen, while it goes back to the sub screen after
moving from the sub screen.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
[1]
[START]
Adjustment finished
[2]
[START]
Main unit chosen
[SUB UNIT] pressed
[RETURN] pressed
Main unit chosen
[RESET]
Sub unit list displayed
[CANCEL] pressed
Sub unit chosen
[RESET] pressed
[INITIALIZE]
pressed
Clear finished
Fig. 7-2
7 - 5
Auto-toner automatic
adjustment perfomed
Automatic gamma
adjustment perfomed
Sub screen
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
PREVENTIVE MAINTENANCE (PM)
Adjustment
finished
7