<Procedure>
(1)
Take off the original glass and lens cover.
(2)
Loosen 4 screws fixing the lens unit.
(3)
Slide the lens unit to the right or left direction using the marks on the lens base as a guide. (Slide
right when the copied ruler is magnified and slide left when the copied ruler is demagnified.)
The following table shows how the reproduction ratio difference between the copied ruler and
actual ruler corresponds to the movement amount of the lens unit.
Reproduction-ratio error
0.1%
0.2%
0.3%
0.4%
0.5%
0.6%
0.7%
0.8%
0.9%
1.0%
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
SETTING / ADJUSTMENT
e-STUDIO206L/256/306/356/456/506
Screw
Lens unit
e-STUDIO207L/257/307/357/457/507
Screw
Lens unit
Movement amount of unit
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
6 - 60
Fig.6-43
Fig.6-44
0.5 mm
0.9 mm
1.4 mm
1.8 mm
2.3 mm
2.7 mm
3.2 mm
3.6 mm
4.1 mm
4.5 mm