5.2.2
Configuring a Normally Closed Supervised Alarm
1.
Install a 2.2 K end-of-line resistor in the alarm circuit.
2.
Connect the alarm to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the AutoDome.
Fig. 5.2 N.C.S. - Normally Closed Supervised Connections
3.
From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input #
to N.C.S. See the table below for contact and condition details.
5.3

Configuring Non-supervised Alarms (inputs 1 through 7)

You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally
Closed (N.C.) alarms.
5.3.1
Configuring a Normally Open Non-supervised Alarm
1.
Connect the alarm to the appropriate input (1 through 7) and ground at the AutoDome.
Fig. 5.3 N.O. - Normally Open Non-supervised Connections
2.
From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input #
to N.O. See the table below for contact and condition details.
Table 5.2 N.O. Non-supervised Conditions
F01U010921 | 1.0 | 2006.10
Alarm 1 or 2 only (Pin 5 or 6)
Dry
DRY
Contact
CONTACT
2.2 K
2.2K
Ground (Pin 7)
AutoDome Programmed N.C.S.
Contact
Alarm Condition
Open
Alarm
Closed
Normal
Short
Tamper
Dry
DRY
Contact
CONTACT
AutoDome Programmed N.O.
Circuit
Alarm Indication
Open
Normal
Closed
Alarm
Installation Manual
ALARM 1 OR 2 ONLY (PIN 5 OR 6)
Dome Connector
DOME CONNECTOR
GROUND (PIN 7)
Alarm Inputs 1 to 7
ALARM INPUTS 1 TO 7
Dome Connector
DOME CONNECTOR
Ground