Bosch AutoDome VG4-A-9230 Series Installation Manual page 35

Modular camera system
Table of Contents

Advertisement

AutoDome Modular Camera System
2.4.3
Power Supply Box Connections
The following figure is a detailed illustration of the Roof or Pipe Mount Power Supply Box,
which includes the fuse specifications.
Fig. 2.6 Power Supply Box Connections for Roof or Pipe Mount
WARNING! Fuse replacement by qualified service personnel only. Replace with same type
!
fuse.
The following table lists the Power Supply Box connectors:
No.
P101 115/230 VAC or 24
P105 Control to Dome
P106 Control In/Out
P107 24 VAC Power to
Table 2.1 Power Box Connections
Bosch Security Systems, Inc.
TRANSFORMER
(115/230VAC
MODELS)
(GROUND SCREW)
24VAC
TO DOME
INTERFACE
BOARD
P101
POWER
CONTROL
CONTROL
IN
LINE NC NEUT
IN/OUT
TO DOME
1 2 3
P106
P105
GND TXD RXD
C+ C-
GND TXD RXD
6 5 4 3 2 1
6 5 4 3 2 1
Power In
Control Data
POWER IN
CONTROL DATA
AND VIDEO IN/OUT
and Video IN/OUT
Connector
Pin 1
Ground
Grounding Screw
Line
VAC Power In
C-
(Fiber Optic Model)
(Biphase)
C-
(Optional)
(Biphase)
Dome
Dome Plug
24 VAC
Installation Manual
Installing Roof Parapet and Pipe Mounts | en
IN/OUT
TO DOME
J102
1/2 in. (15 mm)
FITTING
IN/OUT
IN/OUT
(LED)
C+ C-
3/4 in. (20 mm)
FITTING
Pin 2
Pin 3
Pin 4
NC
Neutral
C+
Earth
RXD (+)
(Biphase)
Ground
(RS-232/485)
C+
Earth
RXD (+)
(Biphase)
Ground
(RS-232/485)
Dome
Earth
Heater
24 VAC
Ground
(24 VAC)
25
FUSE SPECIFICATIONS
VOLTS XF101
XF102
XF103
MAINS HEATER CAMERA
24 V
T 5.0A
T 3.15A T 2.0A
115 V T 1.6A
T 3.15A T 2.0A
230 V T 0.8A
T 3.15A T 2.0A
Pin 5
Pin 6
TXD (-)
Signal
(RS-232/485)
Ground
TXD (-)
Signal
(RS-232/485)
Ground
Heater
(24 VAC)
F01U010921 | 1.0 | 2006.10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Autodome 300 seriesAutodome vg4 seriesVg4-323-ets

Table of Contents