Bosch AutoDome VG4-A-9230 Series Installation Manual page 65

Modular camera system
Table of Contents

Advertisement

AutoDome Modular Camera System
RS232 (3-wire, full-duplex, single-ended, 50 ft. cable limit)
RS232 is a common, single-ended communication protocol used for control. Data transmis-
sion via 3-wires (TDX, RXD, common) is from one transmitter to one receiver at relatively slow
data rates up to 57.6 Kb and short distances up to 50 ft.
NOTICE! After making the wire connections for RS232 operation, reposition the slide switch
i
located on the CPU Module to the camera head inward and away from the LEDs.
Wire Type
Distance
Maximum Baud Rate
Voltage
Termination
Slide Switch
(BIPHASE) C- 1
(BIPHASE) C+ 2
EARTH GROUND 3
SIGNAL GND 6
Fig. 4.4 Connections for RS232 Operation
Fig. 4.5 Position of CPU Switch for RS232 Operation
Bosch Security Systems, Inc.
3-wire (TXD, RXD, common)
50 ft (15 m)
57.6 Kb
+/- 15 V
110 Ω
Toward LEDs (factory default)
AutoDome
AutoDome
Data In/Out
Data In/Out
RXD 4
TXD 5
P105 / P106
P105/P106
Connector
Connector
CPU Module Board
CPU MODULE BOARD
Installation Manual
Cable and Wire Standards | en
Head End
Head End
RS232
RS232
SWITCH
Switch
Location
LOCATION
RS232
RS232
F01U010921 | 1.0 | 2006.10
55
TXD
RXD
GND
LEDs
LEDs

Advertisement