AutoDome Modular Camera System
6.
CAUTION! Be careful not to strip the threads when tightening the Pipe Interface Board
retaining screws.
RETAINING SCREWS (3)
Fig. 2.14 Pipe Interface Board to Dome Cap Assembly
Bosch Security Systems, Inc.
Insert the Pipe Interface Board into the down pipe and fasten the three (3) retaining
screws to secure the board to the Dome Cap.
INTERFACE BOARD
Interface Board
Retaining Screws (3)
Installation Manual
Installing Roof Parapet and Pipe Mounts | en
Pendant Mounting
PENDANT MOUNTING
Screws (2)
SCREWS (2)
F01U010921 | 1.0 | 2006.10