Trouble When Connecting The Optional Card - Sony BRC-300 Service Manual

3ccd color video camera / optical multiplex unit
Hide thumbs Also See for BRC-300:
Table of Contents

Advertisement

4-4-4. Trouble when Connecting the Optional Card

c-6.
The power indicator lights, but the optional card does not function.
Connected to the upper card slot.
Replace the fuse F4002
on the MC board, and
check the power supply
system.
MC board failure
(Q4004, Q4005, or the
peripheral circuit)
Replace the defective
parts or the MC board.
Connect the FFC
between the MC and
CN boards correctly.
Check the connection
between the optional
card and the MC board
to identify the defective
part.
4-22
No
Is the fuse
F4002 normal on the
MC board ?
Yes
Does +12 V exist
No
in L4301 on the
MC board ?
Yes
Is the FFC
No
between the MC and
CN boards correctly
connected ?
Yes
Is any of pins
No
5 to 8 levels in IC3518
set to "L" on the
MC board ?
Yes
One of the following is
defective.
. Pull-up resistors of pins 5 to 9
and 11 to 13 of IC3518.
. IC3518 or the peripheral circuit
Check above in order from the
top to identify the defective part.
c-6
Connected to the lower card slot.
Check the connection
of the optional card.
Is the fuse
F4003 normal on the
MC board ?
Does +12 V exist
in L4302 on the
MC board ?
Is the FFC
between the MC and
CN boards correctly
connected ?
Is any of pins 9, 11
to 13 levels of IC3518
set to "L" on the
MC board ?
FFC: Flexible flat cable
Replace the fuse F4003
No
on the MC board, and
check the power supply
system.
Yes
MC board failure
No
(Q4002, Q4003, or the
peripheral circuit)
Replace the defective
parts or the MC board.
Yes
No
Connect the FFC
between the MC and
CN boards correctly.
Yes
Check the connection
No
between the optional
card and the MC board
to identify the defective
part.