Power On Reset Circuit; Operation At The Time Of A Power Supply; Operation At The Time Of Turn Off; Figure 3.8 Power On Reset Circuit - Toshiba TXZ+ TMPM4MNFYAFG Reference Manual

32-bit risc microcontroller, clock control and operation mode
Table of Contents

Advertisement

3.2.4. Power On Reset Circuit

The Power On Reset Circuit (POR) generates a reset signal when the power is turned on or turned off.
Note: The Power On Reset Circuit may not operate correctly due to the fluctuation of the power supply.
Equipment should be designed with full consideration of the electrical characteristics.
The Power On Reset Circuit consists of a Detection voltage generation circuit, a Reference voltage generation
circuit, and a Comparator.
The supply voltage has referred to DVDD5 (=DVDD5A=DVDD5B).
Supply voltage
Detection
Voltage
generation
circuit

Operation at the time of a power supply

When turn on power supply, while the power supply voltage is lower than Power On Reset Circuit release voltage
(V
), the Power On Reset detection signal is generated. Refer to "Figure 3.1 The reset operation by a Power
PREL
On Reset Circuit" for detail.
While the Power On Reset signal is generated, the reset is asserted to the CPU and the peripherals.

Operation at the time of turn off

When turn off power supply, while the power supply voltage is lower than Power On Reset detection voltage
(V
), the Power On Reset detection signal is generated.
PDET
While the Power On Reset signal is generated, the reset is asserted to the CPU and the peripherals.
Comparator
Reference voltage
generation circuit

Figure 3.8 Power On Reset Circuit

60 / 64
TMPM4M Group(1)
Clock Control and Operation Mode
Power on
Reset detection
PORHV
TXZ+ Family
2022-06-24