Siemens SINUMERIK 840D sl Function Manual page 55

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Comparator signals as digital NCK inputs
All NC functions that are processed as a function of digital NCK inputs can also be controlled
by the signal states of the comparators. The byte address for comparator byte 1 (HW byte
128) or 2 (HW byte 129) must be entered in the MD associated with the NC function
("Assignment of hardware byte used").
Example
"Multiple feedrates in one block" NC function
Entry in channel-specific machine data:
MD21220 $MC_MULTFEED_ASSIGN_FASTIN = 129
This activates various feedrate values as a function of the status of comparator byte 2.
Extended Functions
Function Manual, 03/2009, 6FC5397-1BP10-4BA0
Digital and Analog NCK I/Os (A4)
NCK I/O via PLC
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents