Siemens SINUMERIK 840D sl Function Manual page 167

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

2.8
Link communication
2.8.1
Link variables
Function
Complex systems often feature multiple NCUs, each with multiple channels. Each NCU has
a link communication channel for the purpose of coordinating manufacturing processes
throughout the entire system. Using this, each of the NCUs can exchange data cyclically with
every other NCU in the link grouping.
The link communication channel is based on a memory area on each NCU known as the link
variables memory. The user/machine manufacturer can define both the size and data
structure of the link variables memory on a system-specific basis. The data stored in the link
variables memory is addressed by what are known as link variables;
these are system-global user variables which can be read and written in part programs and
cycles by all NCUs involved in a link grouping if link communication has been configured.
Unlike global user variables (GUD), link variables can also be used in synchronized actions.
On systems without an NCU link, link variables can be used as additional global user
variables alongside standard global user variables (GUD).
Requirements
The following requirements must be met in order to use link variables for cross-NCU data
exchange:
● The link grouping must be installed and configured. See "Configuration of a link grouping
● Link communication must be activated:
Extended Functions
Function Manual, 03/2009, 6FC5397-1BP10-4BA0
Several Operator Panels on Several NCUs, Distributed Systems (B3)
(Page 174)".
MD18780 $MN_MM_NCU_LINK_MASK (activation of NCU link communication)