F215
RR Torque Reference Setpoint #2 (%)
Program
Torque Setting Parameters
This parameter is used to set the gain and bias of the RR input terminal when
this terminal is used as the control input while operating in the Torque Control
mode.
This is accomplished by establishing an associated V/f output pattern for a given
RR input level and motor load.
See
F210
for further information on this setting.
This parameter sets RR Torque Reference Setpoint #2 and is the output torque
value that is associated with setting of F212. This value is entered as 0 – 250%
of the rated torque.
90
Setpoints
RR
Direct Access Number — F215
Parameter Type — Numerical
Factory Default — 100.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 250.0
Units — %
H7 ASD Operation Manual
F215