F411
Number of Poles of Motor
Program
Motor Parameters
This parameter identifies the number of motor poles.
Motor Capacity
Program
Motor Parameters
This parameter identifies the wattage rating of the motor.
Motor Type
Program
Motor Parameters
This parameter identifies the type of motor being used.
Settings:
Toshiba EQP III TEFC
Toshiba EQP III ODP
Toshiba EPACT TEFC
Toshiba EPACT ODP
Other Motor
Allow Autotune
Program
Motor Parameters
This parameter Enables/Disables the Autotune function.
Torque Command
Program
Torque Setting Parameters
When operating in the Torque Control mode, this parameter allows the user to
select the source of the torque command signal.
Settings:
VI/II
RR
RX
RX2 (option)
LED Keypad Option
Binary/BCD Input
Common Serial (TTL)
RS232/485
Communication Card
124
Motor Settings
Motor Settings
Motor Settings
Vector Motor Model
Torque Control
Direct Access Number — F411
Parameter Type — Numerical
Factory Default — 4
Changeable During Run — No
Minimum — 2
Maximum — 16
Direct Access Number — F412
Parameter Type — Numerical
Factory Default — (drive dependent)
Changeable During Run — No
Minimum — 0.10
Maximum — (drive dependent)
Units — kW
Direct Access Number — F413
Parameter Type — Selection List
Factory Default — Toshiba EQP III
TEFC
Changeable During Run — No
Direct Access Number — F414
Parameter Type — Check Box
Factory Default — Enable
Changeable During Run — No
Direct Access Number — F420
Parameter Type — Selection List
Factory Default — RX
Changeable During Run — Yes
H7 ASD Operation Manual