Toshiba H7 Operation Manuals page 175

Adjustable speed drive
Hide thumbs Also See for H7:
Table of Contents

Advertisement

F800
Communication Baud Rate (logic)
Program
Communication Setting Parameters
Settings
This parameter plays a role in the setup of the communications network by
establishing the Baud Rate of the communications link.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Parity
Program
Communication Setting Parameters
Settings
This parameter plays a role in the setup of the communications network by
establishing the Parity setting of the communications link.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Settings:
No Parity
Even Parity
Odd Parity
ASD Number
Program
Communication Setting Parameters
Settings
This parameter plays a role in the setup of the communications network by
assigning an identification (ID) number to each ASD in the communications
network.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
RS485 Communications Time Out Time (RS485)
Program
Communication Setting Parameters
Settings
This parameter plays a role in the setup of the communications network by
setting the time that no activity may exist over the communications link before
the link is severed (Time Out).
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
168
Direct Access Number — F800
Communication
Parameter Type — Numerical
Factory Default — 9600
Changeable During Run — Yes
Minimum — 1200
Maximum — 9600
Units — BPS
Direct Access Number — F801
Communication
Parameter Type — Selection List
Factory Default — Even Parity
Changeable During Run — Yes
Direct Access Number — F802
Communication
Parameter Type — Numerical
Factory Default — 0
Changeable During Run — Yes
Minimum — 0
Maximum — 255
Direct Access Number — F803
Communication
Parameter Type — Numerical
Factory Default — 0
Changeable During Run — Yes
Minimum — 0
Maximum — 100
Units — Seconds
F803
H7 ASD Operation Manual