Additional Functions
13
13.6 Link communication (SW 5.2 and higher)
840D
840D
NCU 571
NCU 572
NCU 573
Value ranges
The different data types have the following value
ranges:
BYTE:
WORD:
DWORD:
REAL:
The various NCU applications sharing access to the
link memory at the same time must use the link
memory in a uniform manner. When the process is
completely separate in time, the link memory can be
occupied differently.
Caution
A link variable write process is only then completed
when the written information is also available to all
the other NCUs. Approximately two interpolation
cycles are necessary for this process. Local writing
to the link memory is delayed by the same time for
purposes of consistency.
For more information, please refer to the Description
of Functions B3 (SW 5)
Programming example
$A_DLB[5]=21
13-456
FM-NC
810D
840Di
0 to 255
–32768 to 32767
–2147483648 to 2147483647
–4.19e-308 to 4.19e-307
The 5th byte in the shared link memory is
assigned value 21.