Siemens sinumerik 840d Programming Manual page 400

Hide thumbs Also See for sinumerik 840d:
Table of Contents

Advertisement

Oscillation
11
11.1 Asynchronous oscillation
840D
840D
NCU 571
NCU 572
NCU 573
This timing is affected by the feedrate override.
Under certain circumstances, an oscillating stroke is
performed before the spark out strokes are started
or the end position approached.
The impression created is that the deactivation
response changes. However, this is not the case.
Setting feed FA
The feedrate is the defined feedrate of the
positioning axis.
If no feedrate is defined, the value stored in the
machine data applies.
Defining the sequence of motions: OSCTRL
The control settings for the movement are set with
enable and reset options.
Reset options
These options are deactivated (only if they have
previously been activated as setting options).
Set options
These options are switched over. When OSE (end
position) is programmed, option 4 is implicitly
activated.
11-400
FM-NC
810D
840Di
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) – 04.00 Edition
08.97
11
 Siemens AG 2000. All rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik fm-ncSinumerik 840diSinumerik 810d

Table of Contents