Frames
6
6.2 Frame variables/assigning values to frames
840D
840D
NCU 571
NCU 572
NCU 573
Function
This feature allows you to access individual data of
a frame, e.g. a specific offset value or angle of
rotation.
You can modify these values or assign them to
another variable.
Sequence
Calling frame
By specifying the system variable $P_UIFRNUM you
can access the current zero offset set with $P_UIFR
or G54, G55, ... ($P_UIFRNUM contains the number
of the currently set frame).
All other stored settable $P_UIFR frames are called up
by specifying the appropriate number $P_UIFR[n].
For predefined frame variables and user-defined
frames, specify the name, e.g. $P_IFRAME.
Calling data
The axis name and the frame component of the
value you want to access or modify are written in
square brackets, e.g. [X, RT] or [Z, MI].
6-200
FM-NC
810D
840Di
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) − 04.00 Edition
12.98
6
Siemens AG 2000. All rights reserved