Gpi Output Setting (Gpi Output Assign Menu) - Sony DVS-9000 User Manual

Switcher system
Hide thumbs Also See for DVS-9000:
Table of Contents

Advertisement

3

GPI Output Setting (GPI Output Assign Menu)

To set the trigger type and so on for each GPI output, display the DCU>GPI
Output Assign menu.
To display the GPI Output Assign menu
In Engineering Setup, select VF5 'DCU' and HF4 'GPI Output Assign.'
The GPI output port setting status appears in the status area.
Making DCU GPI output settings
Use the following procedure.
1
2
3
132
Setup Relating to DCU
In the <Parallel Output Assign> group, press [No Assign].
In the DCU>GPI Output Assign menu, using any of the following methods
select what the setting applies to.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn knob 1 to make the setting.
Knob
Parameter
1
No
In the <Trigger Type> group, select the trigger polarity.
: The trigger causes the relay contacts to be open-circuit or drives
the output high, and holds this state for the specified pulse
width.
: The trigger causes the relay contacts to be shorted or drives the
output low, and holds this state for the specified pulse width.
: Each time the trigger occurs, the relay contacts are alternately
closed or opened, or the output is switched between high and
low.
Status: Depending on the status, the relay contacts are closed or opened,
or the output is switched between high and low.
No Operation: The trigger has no effect on the relay state or output level.
Turning the knobs, select the pulse width and timing to be set.
Knob Parameter
3
Pulse Width
4
Timing
Adjustment
GPI output
Adjustment
Pulse width
Output timing
Setting values
1 to 50
Setting values
1 to 60 (fields)