Single Serial Interface Unit (Rssu) - Toshiba Strata DK14 General Description Manual

Digital business telephone solutions
Hide thumbs Also See for Strata DK14:
Table of Contents

Advertisement

Single Serial Interface Unit (RSSU)

The RSSU contains one RS-232 serial port for connecting an SMDI, SMIS processor, DKAdmin/
DKBackup PC or external modem.
The RSSU provides a cost-effective alternative to the PIOU or PIOUS when only one other serial
I/O port is needed, or when the other features of the PIOU or PIOUS are not required. The RSSU
has a fixed speed of 1200 bps. It does not support SMDR, or the IMDU or RMDS modems.
DK40i – one optional RSSU maintenance interface PCB can be used for connecting a
maintenance PC or external modem (local or remote) to the DK40i.
DK424 – a maximum of three RSSU cards can be supported per DK424.
Table 25
DK424 Interface PCB Options
Interface Options
Zone page interface (unamplified, 4 zones)
Unamplified page output (single zone, 600 ohms, duplex)
Amplified page output (single zone, 3 watts, 8 ohms)
Night transfer or Music-on-hold control relay
Door lock or external amplifier control relay
Alarm Sensor
Remote maintenance modem subassembly (IMDU or RMDS)
(disables TTY output when they are piggy-backed onto the
PIOU/PIOUS or RSIU/RSIS cards)
Remote Maintenance using customer-provided external
modem (requires TTY output port)
SMDR output (RS-232/6-wire modular connector)
MIS for ACD (requires TTY output port)
Voice Mail SMDI (requires TTY output port)
StrataControl and/or DKAdmin PC (requires TTY output port)
1. PIOU, PIOUS, and RSSU each provide one TTY port which can be flexibly programmed for the features marked with X.
RSIU/RSIS can provide up to four flexible TTY/SMDR ports.
2. Maintenance modem, ACD/SMIS, Insight DK, Voice Mail, SMDI and DKAdmin PC Interface each require a separate TTY
output. PIOU, PIOUS, and RSSU provide one TTY output each. RSIU with RSIS PCBs provides up to four TTY outputs.
3. SMDR output will function simultaneously on the same PIOU or PIOUS with one of the following: DKAdmin, remote
modem, SMIS for ACD, Insight DK, or SMDI features.
4. Insight DK, Call Center Viewer and SMIS for ACD requires that the system processor (RCTU PCB) must be equipped with
an RKYS3 or higher feature key.
Strata DK General Description
2
2
2, 4
2
5/99
1
1
RSSU
PIOU
PIOUS
X
X
X
X
X
X
X
(IMDU)
(IMDU)
X
X
3
X
X
X
X
X
2
X
X
Universal Slot PCBs
Option Interface PCBs
RSIU/
1
PEPU
1
RSIS
X
X
X
X
X
X
X
X
X
X
(IMDU)
X
X
3
X
X
X
X
X
X
X
X
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk40iK424Strata dk424

Table of Contents