Electric Cooktop
E30EC65ESS
planning
information
For 30" model:
E30EC65ESS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Optional
Accessories
Granite Countertop
Installation Kit
PN # 903061-9010
50
cooking
Electric Cooktops
13"
max.
cabinet
depth
Side inset
2" min. recommended
distance between rear
4" x 8" opening to route
edge of cutout and
armored cable
nearest combustible
surface above countertop
20
/
" min.
1
4
20
/
" max.
1
2
25" min.
2
/
"
1
2
max.
24"
Installation Specifications
•
Product Weight – 35 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208
Volt, 60 Hertz AC only electrical supply with ground
required on separate circuit fused on both sides of line.
•
Connected Load (kW Rating) @ 240 / 208 Volts =
8.76 / 6.58 kW
•
Amps @ 240 / 208 Volts = 36.2 / 31.4 Amps
•
Always consult local and national electric codes.
•
Allow 2" space below armored cable opening to clear
electrical cable and allow space for installation of junction
box on wall at back of cooktop.
•
Overhead cabinetry should not exceed a 13" max. depth.
•
Allow 30" minimum clearance between top of cooktop
and bottom of unprotected wood or metal overhead
cabinetry.
•
Absolute minimum horizontal distance between overhead
cabinets installed to either side of appliance must be no
less than maximum width of appliance.
•
Allow 24" minimum clearance when bottom of wood or
metal overhead cabinet is protected by not less than
1/8" flame-retardant millboard covered with not less than
No. 28 MGS sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
30
/
"
3
4
21
30
/
"
3
4
/
"
3
8
10"
12"
Approximate location
of junction box
•
Allow 2" minimum clearance between rear edge of cutout
and nearest combustible surface above countertop.
•
Allow 7-1/2" minimum clearance from edge of cooktop to
nearest combustible wall on either side of unit.
•
Drawers not recommended beneath cooktop.
•
To reduce risk of fire when using overhead cabinetry,
install vent hood that projects horizontally a recommended
minimum of 5" beyond bottom of cabinets.
Combination Installations
For installation details refer to Project Planning Section.
•
Cooktop model E30EC65ESS is NOT approved to be
used over any Electrolux ICON
•
Cooktop model E30EC65ESS is approved to be used
in combination with an Electrolux ICON
Vent. (Refer to Drop-In Cooktop / Downdraft Vent
Countertop Preparation page for detailed installation
specifications.)
30" min. for
unprotected cabinet
24" min. for
protected surface
/
"
1
2
4"
18"
min.
7
1
/
" min. to nearest
2
combustible wall
(either side of unit)
6" min.
29
/
"min.
5
8
30" max.
®
Single Wall Oven.
®
30" Downdraft