Slide-In Cooktop / Downdraft Vent Countertop Preparation
Countertop Preparation for 30" & 36" Slide-In Cooktop/ Downdraft Vent Installation
/
" min.
1
4
flat ledge
E
2
/
"
9
16
C
D
1" countertop
overhang
E30DD75ESS/30" Cooktop Cutout Dimensions
30" Cooktop
A
B
C
E30GC74GPS* 29
/
" 29
/
"
22"
15
3
16
16
E36DD75ESS/36" Cooktop Cutout Dimensions
36" Cooktops
A
B
C
E36EC75DSS
35
/
" 35
/
"
22"
15
3
16
16
E36EC75ESS
35
15
/
" 35
3
/
"
22"
16
16
E36EC75HSS
35
/
" 35
/
"
22"
15
3
16
16
E36GC75DSS* 35
/
" 35
/
"
22"
15
3
16
16
E36GC75ESS*
35
/
" 35
/
"
22"
15
3
16
16
E36GC75GSS* 35
/
" 35
/
"
22"
15
3
16
16
E36GC76EPS*
35
/
" 35
/
"
22"
15
3
16
16
E36GC76GPS* 35
/
" 35
/
"
22"
15
3
16
16
*Proper combination installation will require cooktop power cord
to be relocated to underside of unit. (For details, refer to 30" & 36"
Gas Slide-In Cooktop Power Cord Relocation Instructions page.)
Installation Specifications
Cooktop / Downdraft Vent Countertop
Preparation Specifications
•
For detailed Cooktop installation, refer to model-specific
Planning Information page and installation guide on web.
Plan installation so that all required minimum clearances
between cooktop, overhead cabinets and adjacent
vertical walls are provided.
•
Position cooktop / vent cutout so all required minimum
clearances are met.
•
Minimum flat countertop area must meet or exceed
combined overall width and depth as shown. Standard
25" countertop depth is NOT adequate for slide-in
cooktop / vent installations.
•
Separate circuits required for cooktop and vent. (Refer to
product-specific electrical specifications.)
•
Always consult local and national electric and gas codes.
Check local building codes for installation requirements,
as they may vary per locale.
•
Proper combination installation will require 30" & 36" Gas
Slide-In Cooktop power cord to be relocated to underside
of unit. (For details, refer to 30" & 36" Gas Slide-In Cooktop
Power Cord Relocation Instructions page in Project
Planning Section or on the web at electroluxicon.com.)
Downdraft Vent Specifications
•
For detailed Downdraft Vent installations, refer to
model-specific Planning Information page and installation
guide on web.
Downdraft vent cutout opening
in cooktop support platform
7
/
"
1
2
B
A
Studwall
D
E
3"
/
25
/
" 27
/
"
9
13
3
16
4
1
/
"
15
16
Stiffener
D
E
2
25
/
" 33
/
"
13
3
16
4
25
13
/
" 33
3
/
"
16
4
Cooktop Installation Note:
25
/
" 33
/
"
13
3
To ensure proper installation, refer to model-specific installation
16
4
guide on web for cooktop dimensions, cutout dimensions and
25
/
" 33
/
"
13
3
16
4
cabinet requirements.
25
/
" 33
/
"
13
3
16
4
25
/
" 33
/
"
13
3
Countertop Preparation Note:
16
4
Countertop with backsplash may not allow enough flat area for
25
/
" 33
/
"
13
3
16
4
proper installation, 2-13/16" of flat countertop required behind
25
/
" 33
/
"
13
3
16
4
cooktop. No gap required between back of cooktop and front
of downdraft trim piece.
*Standard 25" countertop depth is NOT adequate for slide-in
cooktop / vent installations.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
•
Amps @ 120 Volts = 8.0 Amps
•
Vent unit outside of building only.
•
Vent must be installed in vertical orientation only.
•
1,600 CFM remote exhaust blower (PN # 5304444802)
included with vent – shipped in separate box.
•
Do not use flexible duct. Round duct instead of rectangular
duct recommended, especially when elbows are required.
•
When multiple elbows are necessary, ensure a minimum
of 24" of straight duct between any two elbows.
•
Thermal breaks such as short section of nonmetallic
duct, should be used in areas of extreme cold.
•
For most efficient airflow exhaust, use a straight run or
as few elbows as possible.
•
Cold weather installations should have additional
backdraft damper installed.
•
Installing a Downdraft Vent in combination with any gas
cooking surface will affect optimum burner efficiency.
•
Downdraft Vents can NOT be used in combination with
any cooktop backsplash.
For detailed cooktop and
7
/
"
1
downdraft vent installation
4
specifications, refer to
model-specific product
page and installation
guide on web
Vertical noncombustible surface - rear wall
25
/
"
13
16
/
"min. flat ledge
1
4
Downdraft
chimney top
Countertop*
"
32
Vent unit
Slide-In Cooktop
End of cooktop
Back side of
/
"
13
support platform
cabinet front
16
e l e c t ro l u x i c o n . c o m
planning
information
For models:
Cooktop
E30GC74GPS
E36EC75DSS
E36EC75ESS
E36EC75HSS
E36GC75DSS
E36GC75ESS
E36GC75GSS
E36GC76EPS
E36GC76GPS
Downdraft Vent
E30DD75ESS
E36DD75ESS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
161