Gas and Electric Slide-In Cooktops
13"
max.
1
/
"
2
cabinet
depth
Optional 9" stainless
steel backsplash
(attaches to wall)
Side inset
/
"
5
8
2
/
" min. required distance between rear
1
2
edge of cooktop and nearest combustible
surface above countertop*
25"
22"
3"
min.
24"
Installation Specifications
Product Weight – 190 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.03 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 0.25 Amps
Always consult local and national electric and gas codes.
Cooktop ships with 3/4" factory regulator.
LP Gas conversion kit supplied.
Plan installation to access electrical connection, gas
shutoff valve, and pressure regulator from front of cabinet.
Locate 120V grounded outlet and gas supply in a
30" W x 15-1/2" H area on rear wall, 10" above floor and
6" to right from center of cooktop.
Overhead cabinetry should not exceed a 13" max. depth.
Allow 30" minimum clearance between top of cooktop
and bottom of unprotected wood or metal overhead
cabinetry.
Absolute minimum horizontal distance between overhead
cabinets installed to either side of appliance must be
no less than maximum width of appliance.
48" min.
26
48"
Support
1" min.
platform
Opening to
*If 2
/
" clearance can not be maintained, then optional
1
route gas and
2
stainless steel backsplash or noncombustible backsplash
electrical supply
material must be used – otherwise this installation will
require custom cabinet and countertop dimensions
Allow 24" minimum clearance when bottom of wood or
metal overhead cabinet is protected by not less than
1/8" flame-retardant millboard covered with not less than
No. 28 MGS sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
Allow 2-1/2" minimum clearance between rear edge
of cooktop and nearest combustible surface above
countertop. If required clearance can not be maintained,
then optional stainless steel backsplash or noncombustible
backsplash material must be used – otherwise installation
will require custom cabinet and countertop dimensions.
Allow 10" minimum clearance from edge of cooktop to
nearest combustible wall on either side of unit.
Drawers not recommended beneath cooktop.
To reduce risk of fire when using overhead cabinetry,
install vent hood that projects horizontally a recommended
minimum of 5" beyond bottom of cabinets.
Combination Installations
Cooktop model E48GC76EPS is NOT approved to be
used over any Electrolux ICON
30" min. for
unprotected cabinet
18"
24" min. for
min.
/
"
1
2
protected surface
7
/
"
3
4
10" min. to
nearest combustible wall
(either side of unit)
7
/
"
3
4
1
/
" typical
1
2
countertop
edge
46"
48"
®
Single Wall Oven.
e l e c t ro l u x i c o n . c o m
planning
information
For 48"
gas model:
E48GC76EPS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Optional
Accessories
9" Stainless
Steel Backsplash
PN # ACCBG09-48SI
Black Gas
Valve Knob
PN # 318313302