Electrolux ICON appliances Design Manual page 49

Table of Contents

Advertisement

Electric Cooktops
13"
max.
cabinet
depth
Side inset
2" min. recommended
distance between rear
4"x 8" opening to route
edge of cutout and
armored cable
nearest combustible
surface above countertop
20
/
" min.
1
4
20
/
" max.
1
2
25"min.
2
/
"
1
2
max.
24"
Installation Specifications
Product Weight – 44 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208
Volt, 60 Hertz AC only electrical supply with ground
required on separate circuit fused on both sides of line.
Connected Load (kW Rating) @ 240 / 208 Volts
= 10.16 / 7.63 kW
Amps @ 240 / 208 Volts = 42.0 / 36.5 Amps
Always consult local and national electric codes.
Allow 2" space below armored cable opening to clear
electrical cable and allow space for installation of junction
box on wall at back of cooktop.
Overhead cabinetry should not exceed a 13" max. depth.
Allow 30" minimum clearance between top of cooktop
and bottom of unprotected wood or metal overhead
cabinetry.
Absolute minimum horizontal distance between overhead
cabinets installed to either side of appliance must be no
less than maximum width of appliance.
Allow 24" minimum clearance when bottom of wood or
metal overhead cabinet is protected by not less than
1/8" flame-retardant millboard covered with not less than
No. 28 MGS sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
36
/
"
3
4
36
/
"
3
4
/
"
3
8
10"
12"
Approximate location
of junction box
Allow 2" minimum clearance between rear edge of cutout
and nearest combustible surface above countertop.
Allow 7-1/2" minimum clearance from edge of cooktop to
nearest combustible wall on either side of unit.
Drawers not recommended beneath cooktop.
To reduce risk of fire when using overhead cabinetry,
install vent hood that projects horizontally a recommended
minimum of 5" beyond bottom of cabinets.
Combination Installations
For installation details refer to Project Planning Section.
Cooktop model E36EC65ESS is NOT approved to be
used over any Electrolux ICON
Cooktop model E36EC65ESS is approved to be used
in combination with an Electrolux ICON
Vent. (Refer to Drop-In Cooktop / Downdraft Vent
Countertop Preparation page for detailed installation
specifications.)
30" min. for
unprotected cabinet
24" min. for
protected surface
21
1
/
"
2
4"
18"
min.
7
/
" min. to nearest
1
2
combustible wall
(either side of unit)
6" min.
35
/
"min.
5
8
36"max.
®
Single Wall Oven.
e l e c t ro l u x i c o n . c o m
planning
information
For 36" model:
E36EC65ESS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Optional
Accessories
Granite Countertop
Installation Kit
PN # 903061-9010
®
36" Downdraft
49