Determining Power Supply Status; Removing A Power Supply - HP Integrity rx4610 User Manual

Hp server rx4610 user guide
Hide thumbs Also See for Integrity rx4610:
Table of Contents

Advertisement

Chapter 3

Determining Power Supply Status

When the amber power supply failure LED on the front of the chassis turns on,
determine which power supply is defective by checking the three status LEDs on
each supply. Each power supply has three LEDs that both indicate whether power
is supplied to the power supply and the health of the power supply. The LEDs are
ordered top to bottom on each power supply. Table 3-1 illustrates the states
indicated by the three LEDs.
Table 3-1. Power Supply LEDs
Power Supply Status
No AC power to any power supplies
No AC power to a specific power supply
AC present / Standby output on
DC outputs on and okay
Power supply failure
Current limit
Predictive failure

Removing a Power Supply

To remove a power supply, complete the following procedure:
1. Locate the power supply you want to remove.
2. Push the thumb latch to unlock the power supply handle and pull the
handle down to undock the supply.
CAUTION
Any unused power supply slots must be covered with a
blanking plug. Uncovered slots can disrupt the air flow used
for cooling the system.
Installing Fans and Power Supplies
PWR
PFAIL
(Green)
(Amber)
(Top
(Middle
Position)
Position)
Off
Off
Off
Off
Blinking
Off
On
Off
Off
Off
On
Off
On
Blinking /
Latched
FAIL
(Amber)
(Bottom
Position)
Off
On
Off
Off
On
Blinking
Off
25

Advertisement

Table of Contents
loading