Sony Betacam SX DNW-A100 Maintenance Manual page 370

Digital video hybrid recorder
Hide thumbs Also See for Betacam SX DNW-A100:
Table of Contents

Advertisement

6-9. VPR-17 Board Replacement
10. Component Video Output Level (Another System)
Measuring equipment:
(1) Connect the component waveform monitor (and video monitor) as shown above figure.
(2) For DNW-A100P/A50P/A45P only
Set SUB-ITEM 1 : OUTPUT CAV LEVEL of the setup extended menu ITEM-709 : CAV LEVEL
FORMAT to "D-1".
(3) To enter the maintenance mode, press S1101 (G-1) on the SS-63 board.
(4) Enter C2: AUDIO/VIDEO CHECK.
(5) Enter C21: VIDEO TEST SG.
(6) Video test signal choice
To display the test signal name "100% Color Bars" on the video monitor, turn the search while
pressing the JOG button.
(7) To exit C21: VIDEO TEST SG, press the MENU button once.
(8) To exit C2: AUDIO/VIDEO CHECK, press the MENU button once again.
(9) Enter A2: AUDIO/VIDEO ADJUST.
(10) Enter A20: VPR VR.
6-132
Component waveform monitor
DNW
VIDEO OUTPUT
COMPOSITE 3
a
Y
VIDEO OUTPUT
a
R-Y
COMPONENT
a
B-Y
a : Use the same length cables
(0.5 m)
Video monitor
(terminated with 75 Z)
Component
waveform monitor
CH-1
CH-3
CH-2
75 Z
DNW-A100/A50/A45
DNW-A100P/A50P/A45P

Advertisement

Table of Contents
loading

Table of Contents