6-9. VPR-17 Board Replacement
2. Component Video Output Level Adjustment
Measuring equipment: Component waveform monitor
VIDEO OUTPUT
VIDEO OUTPUT
COMPONENT
a : Use the same length cables
(0.5 m)
(1) Connect the component waveform monitor and video monitor as shown above figure.
(2) For DNW-A100/A50/A45 only
Set SUB-ITEM 1 : OUTPUT CAV LEVEL of the setup extended menu ITEM-709 : CAV LEVEL
FORMAT to "D-1".
(3) To enter the maintenance mode, press S1101 (G-1) on the SS-63 board.
(4) Enter C2: AUDIO/VIDEO CHECK.
(5) Enter C21: VIDEO TEST SG.
(6) Video test signal choice
To display the test signal name "100% Color Bars" on the video monitor, turn the search dial slowly
while pressing the JOG button.
(7) To exit C21: VIDEO TEST SG, press the MENU button once.
(8) To exit C2: AUDIO/VIDEO CHECK, press the MENU button once again.
(9) Enter A2 : AUDIO/VIDEO ADJUST.
(10) Enter A20 : VPR VR.
6-122
DNW
(terminated with 75 Z)
COMPOSITE 3
a
CH-1
Y
a
CH-3
R-Y
CH-2
a
B-Y
Video monitor
Component
waveform monitor
75 Z
DNW-A100/A50/A45