C002 : TOP/END SENSOR
This submenu checks the functions of a tape top sensor and tape end sensor.
(1) Bring a metallic screwdriver near each sensor.
. Check that the characters below the corresponding sensor changes from
"OFF" to "ON!".
c
Never bring the screwdriver into contact with each sensor.
(2) Keep the screwdriver away from each sensor.
. Check that the characters below the corresponding sensor return from "ON!"
to "OFF".
(3) Press the MENU button when terminating the check.
In case of NG
. Check each sensor itself.
. Check the oscillator and detection circuit (on the MS-50 board) for sensors.
. Check the sensor input port (IC115 on the SS-63 board).
Tape end sensor
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
Locations of Tape Top and Tape End Sensors
4-2. TAPE Maintenance Mode (M0)
4-2-2. SERVO CHECK Mode (C0)
SERVO CHECK
INPUT CHECK
C002:TOP/END SENS0R
END
TOP
SENSOR
SENSOR
OFF
OFF
(Ex.)
SERVO CHECK
INPUT CHECK
C002:TOP/END SENS0R
END
TOP
SENSOR
SENSOR
OFF
ON!
Tape top sensor