Operating Conditions; Power Supply; Voltage And Power Requirements; Power Cord - Sony Betacam SX DNW-A100 Maintenance Manual

Digital video hybrid recorder
Hide thumbs Also See for Betacam SX DNW-A100:
Table of Contents

Advertisement

1-3. Operating Conditions

1-4. Power Supply

1-3. Operating Conditions
c
Good air circulation is essential to prevent internal heat
build-up. Place the unit in location with sufficient air
circulation.
Do not block the ventilation holes of the cabinet and the
front and rear panels.
Operating temperature: 5dC to 40dC
(When the inner of the unit becomes less than 5dC, the
hard disk portion does not start up because of entering
into warm up mode.
The inner of the unit becomes 5dC or more, the hard disk
portion start up automatically.)
Operating humidity:
25% to 80% (non-condensing)
Storage temperature: _20dC to 60dC
Locations to avoid:
. Areas where the unit will be exposed to direct sunlight
of any other strong lights.
. Areas near heat sources.
. Dusty areas or areas subject to vibration.
. Areas with strong magnetic field.
. Areas with much electrical noise.
. Areas with much static electricity.
. Areas that is impossible to find a specified room for
installation. (Refer to "1-5. Installation Space".)
. Areas windtight.
Tilt allowance : Within 30d (Do not slant the front and rear
of the unit more than 30d.)
c
Fix the unit securely to avoid drop when the unit is operat-
ed at not-horizonal place.
1-4. Power Supply

1-4-1. Voltage and Power Requirements

This unit's power line has a switching regulator.
c
Be sure to operate the unit within the range of following
power voltage.
AC 100 to 240 V ± 10%
Power voltage:
Power frequency:
50 Hz or 60 Hz
Power consumption:DNW-A100/A100P; 320 W (320 VA)
DNW-A50/A50P; 300 W (300 VA)
DNW-A45/A45P; 300 W (300 VA)
1-2
Rush current:
Power voltage 100 V IN; 10 A
Power voltage 240 V IN; 20 A
The power consumption just described is includes the
power consumption of a optional board BKDW-505 or
BKDW-506.
n
AC power supply is required a capacity which is commen-
surate with rush current.
If the capacity of the AC power supply is not enough, the
breaker of AC power of a supply side may operate or this
unit may not operate normally.

1-4-2. Power Cord

w
Use the specified power cord only when connecting.
Never use a injured power cord.
Power cord for the customer in the U.S.A. and Canada.
1Power cord set (approx. 2.4 m) ! 1-551-812-11
2Plug holder (Black)
1
Power cord for the customer in the United Kingdom.
1Power cord set (approx. 2.5 m) ! 1-782-929-11
2Plug holder (Brown)
1
If the unit destined for Europe is used in the area except
the United Kingdom, please contact your local Sony Sales
Office/Service Center.
2-990-242-01
AC inlet
2
(DNW)
3-613-640-11
AC inlet
2
DNW-A100/A50/A45