Monitoring of system
pressure and
oil temperature
"
Table 33: Overview of
Drainage
Parameter
Description
P-0-1272
Actual value
P-0-1389[15]
Debouncing time
P-0-1389[12]
Threshold value
P-0-1389[17]
Drainage time
P-0-1389[22]
Degassing time
P-0-1389[16]
Pause time
Table 34: Parameter P-0-1418
P-0-1418
Degassing valve
P-0-1418 Bit 0
Drain valve
P-0-1418 Bit 1
The monitoring of the system pressure becomes active when the pressure falls
below the threshold value for a debouncing time.
The monitoring of the oil temperature becomes active when the pressure exceeds
the threshold value for a debouncing time.
In both cases, a warning is issued.

5.3.7 RGB LED as status display

The LED is located in the upper door of the CytroBox. The color cyan means OK,
yellow means warning and red means error. The LED is inactive in service mode.
Table 35: Color assignment
LED color
Description
Red
Drive error
Yellow
Drive warning
Nothing amiss –
Cyan
neither error nor warning

5.3.8 Description of parameters and diagnosis

The following chapter includes a list of all available parameters as well as all
occurring errors and warnings.
"
parameters
Unit
%
ms
%
sec
sec
sec
Description
Disabled
Valve for degassing closed
Enabled
Valve for degassing open
Not activated
Valve for drainage closed
Activated
Valve for drainage open
CytroBox, RE 51057-B/11.19, Bosch Rexroth AG
Product information 39/128
Default
-
0
180
15
30
600