Technical Data - Bosch rexroth CytroBox Operating Instructions Manual

Hydraulic power unit
Table of Contents

Advertisement

116/128 Technical data

General
Installation position
Line connections
Place of installation
Ambient temperature range (during operation)
Weight (depending on configuration level) without oil
Material
Hydraulic
Maximum operating pressure
Maximum flow
Maximum oscillating volume
Maximum tank capacity
Maximum temperature range of the hydraulic fluid
Hydraulic fluids
Maximum admissible degree of contamination of the hydraulic
fluid; cleanliness class according to ISO 4406 (c)
Pressure filter
2)
Filling level monitoring
Temperature
monitoring (hydraulic fluid)
Pump
1)
The cleanliness classes specified for the components must be adhered to in hydraulic systems.
Effective filtration prevents faults and simultaneously increases the life cycle of the components.
For selecting the filters, see www.boschrexroth.com/filter.
2)
Directly mounted at the block.
Bosch Rexroth AG, CytroBox, RE 51057-B/11.19
16 Technical data
▶ Pressure port
▶ Return flow
▶ Tank
▶ Steel components
▶ Base
▶ Filter rating
▶ Early warning
▶ Shut-off
▶ Early warning
▶ Shut-off
▶ Minimum flow
▶ Hydraulic fluid viscosity range
(see data sheet 91485)
For further information and data on the use of other hydraulic fluids,
please contact us.
Vertical
G1 1/4
G1 1/2
Industrial building; stationary application
°C +10 ... +40
kg 500 ... 550 depending on the equipment
Plastic (PP)
Galvanized, painted, powder-coated
Polymer concrete
bar 315, see characteristic curves on page 12 in the
data sheet 51057
l/min 160, see characteristic curves on page 12 in the
data sheet 51057
l 50
l 150
°C +5 ... +70
Mineral oil HLP according to DIN 51524
Class 20/18/15
1)
µm 10
l
Adjustable by means of parameters, see page 33.
l
°C
Adjustable by means of parameters, see page 33.
°C
l/min 0
2
mm
/s ≦ 1000 in case of cold start
1000 ... 400 warm-up phase
400 ... 16 continuous operation

Advertisement

Table of Contents
loading