Siemens SINUMERIK 840D Diagnostics Manual page 69

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
6415
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
6416
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
6417
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
6418
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
TO unit %1 tool %2 with tool edge no. %3 has reached tool monitor warning limit
%1 = TO unit
%2 = Tool identifier
%3 = Cutting edge number
This message informs that at least one cutting edge of the time or quantity monitored tool
has reached its monitoring limit. The alarm was triggered through the OPI interface
(MMC, PLC). The channel context is not defined. The TO unit was specified for this rea-
son.
- Interface signals are set.
- Alarm display.
For information only. The user must decide what to do.
Clear alarm with the Delete key or NC START.
Channel %1 tool %2 with tool edge no. %3 has reached tool monitor warning limit
%1 = Channel number
%2 = Tool identifier
%3 = Cutting edge number
This message informs that at least one cutting edge of the time or quantity monitored tool
has reached its monitoring limit. The limit was detected in the channel context. The alarm
originated during NC program execution.
- Interface signals are set.
- Alarm display.
For information only. The user must decide what to do.
Clear alarm with the Delete key or NC START.
TO unit %1 tool %2 with tool edge no. %3 has reached tool monitoring limit
%1 = TO unit
%2 = Tool identifier
%3 = Cutting edge number
This message informs that at least one cutting edge of the time or quantity monitored tool
has reached its monitoring limit. The alarm was triggered through the OPI interface
(MMC, PLC). The channel context is not defined. The TO unit was specified for this rea-
son.
- Interface signals are set.
- Alarm display.
For information only. The user must decide what to do.
Clear alarm with the Delete key or NC START.
Channel %1 tool %2 with tool edge no. %3 has reached tool monitoring limit
%1 = Channel number
%2 = Tool identifier
%3 = Tool number
This message informs that at least one cutting edge of the time or quantity monitored tool
has reached its monitoring limit. The limit was detected in the channel context. The alarm
originated during NC-program execution.
- Interface signals are set.
- Alarm display.
For information only. The user must decide what to do.
Clear alarm with the Delete key or NC START.
1 Alarms
1-69

Advertisement

Table of Contents
loading

Table of Contents