SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Incorrect address
When the data memory was being tested during power-up, it was detected that the written
bitmap could not be read back.
Cause: Hardware error on control module.
Replace the control module.
0003H
Computing time overrun
1 = Bit 0 : Level 3 time slice (MONCYC) (MD 1300)
2 = Bit 1 : 4 msec time slice
4 = Bit 2 : 1 msec time slice
8 = Bit 3 : PC time slice
10 = Bit 4 : SC time slice
20 = Bit 5 : IC time slice
40 = Bit 6 : SI time slice
A0 = Startup, synchronization
B0 = Background computing time
-
The computing time of the drive processor is no longer sufficient for the selected functions
in the specified cycle times. This error normally only occurs in conjunction with startup
functions in the case of default values (FFT measurement, step response). SINUMERIK
Safety Integrated: Monitoring cycle too short.
(MD 1001)
(MD 1000)
(MD 1300)