In redefining the pole with G110, G111 or G112 in polar coordinates, the value range of
the pole angle specified under keyword AP=... has been exceeded. It covers the range
from -360 to +360 degrees with a resolution of 0.001 degrees.
Definition of terms:
• Specification of end of block point with polar angle and polar radius, referring to the cur-
rent pole (preparatory functions: G00/G01/G02/G03).
• New definition of the pole with polar angle and pole radius, referring to the reference
point selected with the G function. G110 ... last programmed point in the plane, G111 ...
zero point of the current work, G112 ... last pole
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct NC part program. The permissible input range for the polar angle is between the
values -360 degrees and +360 degrees with a resolution of 0.001 degrees.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 pole programmed incorrectly
%1 = Channel number
%2 = Block number, label
When defining the pole, an axis was programmed that does not belong to the selected
processing level. Programming in polar coordinates always refers to the plane activated
with G17 to G19. This also applies to the definition of a new pole with G110, G111 or
G112.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct the NC part program. Only the two geometry axes may be programmed that
establish the current machining plane.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 polar coordinates programmed incorrectly
%1 = Channel number
%2 = Block number, label
The end point of the displayed block has been programmed both in the polar coordinate
system (with AP=..., RP=...) and in the Cartesian coordinate system (axis addresses X,
Y,...).
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct the NC part program - the axis motion may be specified in one coordinate system
only.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 polynominal degree greater than 5 programmed for polynom-
inal interpolation
%1 = Channel number
%2 = Block number, label
A polynominal degree greater than five was programmed for the polynominal interpola-
tion. You can only program polynomials up to the 5th degree.