1 Alarms
Reactions:
Remedy:
Program Continuation:
12700
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12701
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12710
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-170
- Correction block
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 contour definition programming not allowed as modal sub-
program is active
%1 = Channel number
%2 = Block number, label
In the external language mode, a block is programmed with contour definition and a
modal cycle is active at the same time. Because of unclear address assignment (e.g. R =
radius for contour definition or return plane for drilling cycle) contour definition program-
ming must not be used when a modal cycle is active.
- Correction block
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 illegal interpolation type for contour definition active
%1 = Channel number
%2 = Block number, label
In one contour definition block, G01 is not active as interpolation function. In one contour
definition block, the linear interpolation always has to be selected with G01. G00, G02,
G03, G33 etc. are not permitted.
- Correction block
- Interface signals are set.
- Alarm display.
Modify part program. Program linear interpolation G01.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 illegal language element in external language mode
%1 = Channel number
%2 = Block number, label
The programmed language element is not allowed or unknown in external language
mode. Only the language elements from Siemens mode which are used for subprogram
calls (except for Lxx) and the language constructs for program repetition with REPEAT
(UNTIL) are allowed.
- Correction block
- Interface signals are set.
- Alarm display.
Modify part program.
Check that the language command is available in Siemens mode. Switch to Siemens
mode with G290. Program the command in the next block and switch back to the external
language mode in the following block.
Clear alarm with NC START or RESET key and continue the program.
 Siemens AG, 2004. All rights reserved