Siemens SINUMERIK 840D Diagnostics Manual page 243

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
15395
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15400
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15410
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15420
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Set the desired gear status via asynchronous subprogram.
Clear alarm with the Delete key or NC START.
Channel %1 master-slave not executable during block search
%1 = Channel number
A master-slave coupling is to be closed in the part program via the instruction MASLON.
The position offset $P_SEARCH_MASLD, however, cannot be correctly calculated during
block search, as the axes to be coupled are located in different channels.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Make sure that all relevant axes are in the same channel.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 selected initial init file does not exist
%1 = Channel number
%2 = Block number, label
The operator has selected an INI block for a read, write or execution function which:
1. Does not exist in the NCK range or
2. Does not have the necessary protection level required for performing the function.
- Alarm display.
Please inform the authorized personnel/service department. Check whether the selected
INI block is contained in the file system of the NCK. The present protection level must be
selected to be at least equal to (or greater than) the protection level that has been defined
for the read, write or execution function at the time of creating the file.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 initialization file contains invalid M function
%1 = Channel number
%2 = Block number, label
The only M function allowed in an Init block is the M02, M17 or M30 end-of-program func-
tion.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remove all M functions from the Init block except for the end identifier.
An Init block may contain value assignments only (and global data definitions if they are
not defined again in a program that can be executed later) but no motion or synchronous
actions.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 instruction in current mode not allowed
%1 = Channel number
%2 = Block number, label
1 Alarms