Installing
3.3 Installing supplementary system components
Mounting the CX32-2 directly on a mounting surface
A spacer is pre-assembled on the CX32-2. To mount the CX32-2 directly on a mounting
surface, you must first disassemble the spacer as follows:
Table 3-3
Disassembling the CX32-2 spacer
Loosen the screws on the mounting rail
(M3, Torx T10) and remove the rail.
The CX32-2 can now be mounted directly on a mounting surface, e.g. a wall of the control
cabinet. It is fastened with 2 screws M6 / 6 Nm.
48
Loosen the screws of the spacer (M3,
Torx T10) and remove the spacer.
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
Fasten the mounting rail to the CX32-2
again without spacer (tightening torque
0.8 Nm).