Figure 3-26
3. Select a directory or create a new one. Then press the "OK" softkey to confirm your
selection.
You are prompted to assign a name for the future certificate.
4. Enter the certificate name here. Then press the "OK" softkey to confirm your entry.
The certificate is then saved in the selected archive folder as RTF file. As a result of the
RTF format, the certificate can be subsequently supplemented, e.g. to include a machine
diagram.
3.3.5

Acceptance test mode

For specific test types, the acceptance test mode is activated for the axis and/or the drive
involved while the test is being performed.
Activating the acceptance test mode has the following effects:
Acceptance test
Axis: Safely reduced speed (SG)
Axis: Safe operating stop (SBH)
Drive: Safely reduced speed (SG)
Drive: Safe operating stop (SBH)
Axis: Safe software limit switches (SE)
SINUMERIK Operate acceptance test
Function Manual, 08/2018, A5E39460574B AC
3.3 SINUMERIK 840D sl - system-integrated Safety Functions
Example - Safety acceptance, save certificate
Acceptance test wizard of SINUMERIK Operate
Effects
● Safety Integrated-specific power on
alarms can be acknowledged using a
channel reset.
● The setpoint speed limit is deactivated.
● It is run with $MA_MAX_AX_VELO.
The software limit switches of the axis are
deactivated.