Calling the acceptance test wizard
MENU SELECT > Commissioning > Safety > Acceptance test
Figure 3-1
Descriptions of the individual test cases and information to be entered in the acceptance test
wizard can be found directly in the respective input screens.
Working with the acceptance test wizard
Available test types/setting ranges
In the left-hand section of the acceptance test basic screen, the test types (switch-off signal
path, external stops, SPL inputs/outputs, etc.) of the SI functions, currently configured in the
system, are displayed in a selection list. Test instances can only be created for these – or tests
carried out for these.
Safety Integrated functions
With the acceptance test, tests can be carried out with safety functions integrated in the system
(SINUMERIK Safety Integrated) as well as for axes with safety functions integrated in the drives
(SINAMICS Basic and Extended Functions). The test results for both versions are included in
the certificate that is finally generated.
Access rights
In order that the acceptance test can be started, for all of the components within the scope of
the SI functions to be tested (NC, drive) access rights that permit changes to be made to
machine data and parameters must be active.
SINUMERIK Operate acceptance test
Function Manual, 08/2018, A5E39460574B AC
3.2 SINUMERIK 828D/840D sl - drive-based Safety functions
SINUMERIK Operate - Acceptance test wizard
Acceptance test wizard of SINUMERIK Operate
25