Manufacturer-Specific Configurations (Slatw.ini) - Siemens SINUMERIK 828D Function Manual

Sinumerik operate acceptance test
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

The SINAMICS acceptance test mode is integrated in the SINUMERIK Operate acceptance
test wizard, where you parameterize the time and activate the mode in the associated
SINUMERIK Operate input screens, rather than directly via parameters.
Unexpected axis motion at speed setpoint ≠ 0
If a speed setpoint ≠ 0 is present, the active stop function SS2 is set, and the motor is at a
standstill (active SOS), the axis starts to move as soon as the acceptance test is activated.
If persons are in the danger zone, accidents causing death or severe injury can occur.
● Take suitable measures to ensure that nobody is in the danger zone.
The limit value violations required and intended for the acceptance test are possible while the
acceptance test mode remains active. For instance, the setpoint speed limits are no longer
active in the acceptance test mode. To ensure that this state is not inadvertently retained, the
acceptance test mode is automatically exited after the parameterized time (p9558).
Normally, SOS can be selected directly or via SS2. To be able to trigger violation of the SOS
standstill limits with the acceptance test mode active (also in the "SS2 active" state) the setpoint
is enabled again by the acceptance test mode after deceleration and transition to SOS to allow
the motor to move. When an SOS violation is acknowledged in the active acceptance test
mode, the actual position is adopted as the new stop position so that an SOS violation is not
immediately identified again.
3.2.6

Manufacturer-specific configurations (slatw.ini)

General user-specific and test-specific settings can be made in file slatw.ini.
For SINUMERIK Operate, the file is located under the following directory:
● .../siemens/sinumerik/hmi/cfg
To activate user-specific settings, a file must be created under the same name in the user
directory:
● .../user/sinumerik/hmi/cfg
The subsequently described changes can be entered into this file.
DBxy.DBXy.z
SINUMERIK Operate acceptance test
Function Manual, 08/2018, A5E39460574B AC
WARNING
Acceptance test wizard of SINUMERIK Operate
3.2 SINUMERIK 828D/840D sl - drive-based Safety functions
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents