11/2006
9744
MD number
Default setting: –1
Change becomes effective after: IMMEDIATELY
Data type: LONG
Significance:
9745
MD number
Default setting: –1
Change becomes effective after: IMMEDIATELY
Data type: LONG
Significance:
9746
MD number
Default setting: –1
Change becomes effective after: IMMEDIATELY
Data type: LONG
Significance:
9748
MD number
Default setting: 0
Change becomes effective after: IMMEDIATELY
Data type: DOUBLE
Significance:
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D sl Commissioning Manual CNC: ShopMill – 11/2006 Edition
$MM_CMM__M_CODE_T OOL_FUNC_3_OFF
M code for tool–specific function 3 OFF
Min. input limit: – 1
Protection level: 3/4
This MD is used to define an M command for tool–specific function 3.
The value –1 means that the M function is not output.
If both M commands of function 3 =–1, the corresponding field is not displayed on the inter-
face.
$MM_CMM__M_CODE_T OOL_FUNC_4_ON
M code for tool–specific function 4 ON
Min. input limit: – 1
Protection level: 3/4
This MD is used to define an M command for tool–specific function 4.
The value –1 means that the M function is not output.
If both M commands of function 4 =–1, the corresponding field is not displayed on the inter-
face.
$MM_CMM__M_CODE_T OOL_FUNC_4_OFF
M code for tool–specific function 4 OFF
Min. input limit: – 1
Protection level: 3/4
This MD is used to define an M command for tool–specific function 4.
The value –1 means that the M function is not output.
If both M commands of function 4 =–1, the corresponding field is not displayed on the inter-
face.
$MM_CMM_MKS_POSITION_MAN_MEAS
Position man. tool measurement with fixed point
Min. input limit: –
Protection level: 3/4
This MD is used to define the position of the fixed point in the machine coordinate system if
a fixed point must be used as reference point for manual tool measuring.
The position of the fixed point can also be determined via the function "Manual machine"
→
"Measuring tool"
"Adjusting fixed point". The determined position is then automatically
entered into this MD.
7.2
Display machine data for ShopMill
Max. input limit: 32767
Units: –
Valid as of software version
ShopMill 7.1
Max. input limit: 32767
Units: –
Valid as of software version
ShopMill 7.1
Max. input limit: 32767
Units: –
Valid as of software version
ShopMill 7.1
Max. input limit: –
Units: mm
Valid as of software version
ShopMill 6.4
7 Machine Data
→
7-65