15 SW Installation/Update and Data Backup
15.3 Data backup
15-490
Following menu:
What kind of disk partitioning do you want?
1
Standard Partitioning (default)
2
User-defined Partitioning
Your Choice [1,2]?
Standard partitioning (default)
The hard disk partitioning of the PCU is set to the initial state by auto-
matic parameterization by Norton Ghostt.
User-defined partitioning
You can adapt the sizes of the hard disk partitions on the PCU manually
in Norton Ghostt.
Answer the confirmation question with "Y" to start restoring.
Norton Ghostt is now started. The following information is displayed in the
message window that opens:
– The progress of the data transfer is displayed.
– The paths are displayed.
– The volume of data to be transferred is displayed.
Size of backup copy with compressing: 4.8GB hard disk –> approx. 330MB
image file
Time for transfer: approx. 15min.
Notice
If you abort the transfer, inconsistent data will be available on the PCU, and the
system can possibly no longer be booted.
To boot the PCU, you will need a boot diskette.
Norton Ghostt closes automatically when the import process is completed.
8. With restoring the backup copy to the PCU, the last valid computer name
with which the PCU has been identified on the network has been overwrit-
ten.
To make sure that the PCU is assigned a valid computer name again, you
must type a new name of the computer. The following menu will appear:
PLEASE SELECT
1
Input Machine Name MANUALLY
2
Input Machine Name RANDOMLY
9
Abort
Your Choice [1,2,9]?