Siemens SINUMERIK 840Di Manual page 387

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

06.03
Machine data
Table 10-50
Digital and analog I/Os: Machine data
Number
General ($MN_ ...)
10300
FASTIO_ANA_NUM_INPUTS
10310
FASTIO_ANA_NUM_OUTPUTS
10320
FASTIO_ANA_INPUT_WEIGHT
10330
FASTIO_ANA_OUTPUT_WEIGHT
10350
FASTIO_DIG_NUM_INPUTS
10360
FASTIO_DIG_NUM_OUTPUTS
10362
HW_ASSIGN_ANA_FASTIN
10364
HW_ASSIGN_ANA_FASTOUT
10366
HW_ASSIGN_DIG_FASTIN
10368
HW_ASSIGN_DIG_FASTOUT
10380
HW_UPDATE_RATE_FASTIO
10382
HW_LEAD_TIME_F ASTIO
10384
HW_CLOCKED_MODULE_MASK
10394
PLCIO_NUM_BYTES_IN
10395
PLCIO_LOGIC_ADDRESS_IN
10396
PLCIO_NUM_BYTES_OUT
10397
PLCIO_LOGIC_ADDRESS_OUT
10530
COMPAR_ASSIGN_ANA_INPUT_1
10531
COMPAR_ASSIGN_ANA_INPUT_2
10540
COMPAR_TYPE_1
10541
COMPAR_TYPE_2
Channel-specific ($MC_ ...)
21220
MULTFEED_ASSIGN_FASTIN
Setting data
Table 10-51
Digital and analog I/Os: Setting data
Number
General ($SN_ ...)
41600
COMPAR_THRESHOLD_1
41601
COMPAR_THRESHOLD_2
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
Identifier
Number of active analog NC inputs
Number of active analog NC outputs
Weighting factor for analog NC inputs
Weighting factor for analog NC outputs
Number of active digital NC input bytes
Number of active digital NC output bytes
Hardware assignment of the external analog NC
inputs
Hardware assignment of the external analog NC
outputs
Hardware assignment of the external digital NC
inputs
Hardware assignment of the external digital NC
outputs
Update rate of the synchronous external NC I/Os
Lead time of the synchronous external NC I/Os
Synchronous processing of the external NC I/Os
Number of directly readable input bytes of the PLC
I/Os
Start address of the directly readable input bytes of
the PLC I/Os
Number of directly writeable output bytes of the
PLC I/Os
Start address of the directly writeable
output bytes of the PLC I/Os
Hardware assignment of the NC analog inputs for
comparator byte 1
Hardware assignment of the NC analog inputs for
comparator byte 2
Parameterization for comparator byte 1
Parameterization for comparator byte 2
Assignment of the input bytes of the NC I/Os for
"Several feedrates in a block"
Identifier
Threshold values for comparator byte 1
Threshold values for comparator byte 2
10 NC Start-Up with HMI Advanced
10.6 Digital and analog I/O devices
Name
Name
Ref.
V1
Ref.
10-387

Advertisement

Table of Contents
loading