Parameterization Of The Mcp - Siemens SINUMERIK 840Di Manual

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

06.03
References
Automation
system
5.4.2

Parameterization of the MCP

Electrical
connection
Power supply interface
1
SHIELD M24
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
The basic PLC program is part of the SINUMERIK 840Di installation.
The installation of the basic PLC program as a SIMATIC S7 library is described
in Subsection 8.2.2 (page 8-251) in detail.
SIMATIC Manager STEP7
SIMATIC Manager S7 is used for adapting the basic PLC and user programs
(e.g. call of FC 25).
The following manuals are required to start up an MCP:
/FB1/
Description of Functions, Basic Machine: P3, Basic PLC Program
Description of the program structure and modules of the basic PLC program.
/BH/
Operator Components, Manual
Description of MCP (interfaces, electrical connection, etc.)
/Z/
Catalog NC Z
Components required for connection: Cables, connectors, etc.
To start up the MCP, the automation system must be electrically and mechani-
cally connected completely with respect to NCK, PLC and MCP.
The drives must be secured against accidental moving.
The MCP's electrical connections and connections for MPI communication are
made using the interfaces on the rear side of the MCP.
Connection for equipotential bonding conductor
X20
X10
MPI interface
2
3
P24
Fig. 5-4
Position of interfaces on rear panel of MCP
5 MPI Communication
5.4 Machine control panel (MCP)
LEDs1...4
1 2 3 4
3
1
S3
4
2
EMERGENCY
S3 DIP switch
STOP button
connections
5-141